Product information
Dr. Odin OAS103 Aneroid Sphygmomanometer (Table Top) is a manual blood pressure monitoring device designed for healthcare professionals and trained individuals. It includes an aneroid gauge, inflation bulb, control valve, PVC tubing, and arm cuff. The device operates through an auscultatory technique using a stethoscope. The unit is built with a flat base to stabilize it during use and offers mechanical pressure measurement without batteries or electronics.
Uses:
It is used to measure systolic and diastolic blood pressure manually, typically in clinical or home care settings by individuals trained in auscultatory techniques.
Net Quantity:
1 Unit
Product Specifications and Features:
- This device is equipped with a square aneroid dial that displays pressure readings ranging from 0 to 300 mmHg, designed for manual blood pressure monitoring.
- The pressure gauge offers a tolerance of ±4 mmHg, providing visibility into minor variations in measured values.
- It includes a standard adult-sized arm cuff that fits arm circumferences between 27 to 36 cm, suitable for most users.
- The inflation mechanism includes a latex-free rubber bulb and an adjustable release valve to manually control air pressure during the reading.
- The unit features a stable tabletop design with a wide base, making it suitable for placement on desks or examination tables.
- A PVC tube connects the cuff to the manometer and inflation bulb, which may allow consistent airflow during use.
- It is designed to function effectively within an operational environment of 10°C to 40°C and relative humidity between 15% and 85%.
- Product dimension: 18.5 x 16.5 x 17.5 cms.
Directions for Use:
- Sit on a flat surface. Position the left arm so it is level with the heart.
- Wrap the cuff midway between the shoulder and elbow, over the brachial artery.
- Ensure the cuff fits comfortably and is not too tight or too loose.
- Place the stethoscope under the cuff over the artery. Inflate using a bulb to 180–200 mmHg.
- Slowly release pressure using the valve and listen for pulse sounds with a stethoscope.
- Note the first and last audible pulse as systolic and diastolic values.
- Or use as instructed in the user manual.
Safety Information:
- Manometer: Aneroid gauge requires minimal care and maintenance.
- The manometer may be cleaned with a soft cloth but should not be dismantled under any circumstances.
- Gauge accuracy can be checked visually; ensure the needle rests at zero position when the unit is fully deflated.
- A manometer whose indicator needle is not resting at zero point is not acceptable for use.
- Cuff Cleaning and Disinfecting: Use one or more of the following methods and allow to air dry: Wipe with 70% isopropyl alcohol. Wipe with 0.5% bleach and water solution. Do not iron cuff. Do not heat or steam-sterilise cuff.
- Storage: After measurement, fully exhaust cuff then wrap cuff around gauge and bulb and store in zippered leather carrying case.
- Disposal: When your sphygmomanometer has reached its end of life, dispose of it in accordance with regional and national environmental regulations.
- Do not allow a blood pressure cuff to remain on patient for more than 10 minutes when inflated above 10 mmHg. This may cause patient distress, disturb blood circulation, and contribute to the injury of peripheral nerves or death.
- Safety and effectiveness with neonate cuff sizes 1 through 5 is not established.
- If this equipment is modified, appropriate inspection and testing must be conducted to ensure its continued safe use.
- Do not apply cuff to delicate or damaged skin. Check cuff site frequently for irritation.
- Only use the cuff when the range marking indicated on the cuff shows that the proper cuff size is selected, otherwise erroneous readings may result.
- Allow space between patient and cuff. Two fingers should fit in this space if the cuff is correctly positioned.
- Do not apply to limbs used for IV infusion.
- Patient should remain still during measurement to avoid erroneous readings.
- Read the user manual before use.
Quick Tips:
- Always check if the needle is at zero before using it.
- Avoid pressing too hard on the stethoscope head during use.
Frequently bought together

Dr. Odin OAS103 Aneroid Sphygmomanometer (Table Top)
₹2754

Crescent Ultimate Royale 6 In 1 Quick Relief Body Massager Light Green
₹632




Other information
Content details
Manufacturer details
Address: A)Plot No. 45, Ind. Area, Phase-II, Panchkula - 134113 (Haryana) - India
Marketer details
Address: Plot No. 45, Industrial Area Phase II, Panchkula, Haryana 134113 India